OBSCURAFORGE is a pinhole camera simulator and blueprint lab. Compare hole size, camera depth, exposure and synthetic image blur before choosing a six-panel paper-camera plan. Use its calculations to prepare a physical test.
Hands-on check: 11 November 2026. We tested the English and Korean interfaces in Chrome, including a 390 px mobile layout. The figures below are observed browser outputs. We did not build a camera, expose photographic material or verify downloaded files.
On this page
Key takeaways
Separate the two exposure numbers. Changing the aperture updates the meter, but the manual exposure does not automatically follow it. At EV 5, our computed reading reached 2.4e+3 seconds while Match metered exposure stopped at the input maximum of 120 seconds.
Keep comparisons controlled. Use the same scene, orientation, print style and inspection zoom for A and B. The proxy minimum and the Rayleigh starting point use different criteria; neither is a measured guarantee for your handmade hole.
Save settings before fabrication. A setup URL reproduced our numeric configuration in a new tab. The local archive let us restore two experiments across the language pages. Neither observation establishes a cloud backup or a finished, light-tight camera.
What this pinhole camera simulator does
The official interface is titled Pinhole Camera Simulator & Blueprint Lab, under the OBSCURAFORGE brand. Explore exposes basic geometry and exposure controls; Precision adds film width, subject distance, wavelength, pinhole shift, EV and ISO; Compare places a saved reference beside the current synthetic image. English and Korean pages are available through the language navigation.
A normal calculator can tell you an f-number. This pinhole camera workspace also connects that number to field of view, relative illumination, geometric blur, a diffraction estimate and a paper-box layout. It helps answer a practical question: should a planned box be shallower, should the foil hole be smaller, or is a dim preview simply using the wrong manual time?
The scene choices include a mountain retreat, an architectural study and a resolution chart. Natural colour, monochrome and a negative study change the display. View upright rotates the projected image for easier reading; Inspect 2× enlarges inspection. These are viewing aids. They do not turn the educational scene into a scan of a real negative.
Prepare a useful experiment
For a first session, bring three dimensions: the approximate hole diameter, the distance from hole to film, and the intended image width. The default 36 mm width is a modelling input, not proof that a particular film holder will fit. If you are working with photographic paper, keep the product and processing notes nearby instead of borrowing an arbitrary paper ISO from a web example.
Record a baseline before adjusting anything. Our baseline used a 0.45 mm hole, 100 mm depth, 36 mm image width, a subject at 2,000 mm, 550 nm wavelength, zero shift, EV 12 and ISO 100. Manual exposure was 12 seconds. A notebook row containing all those values is much more useful than a screenshot labelled only “sharp”.
Use millimetres consistently. A wavelength of 550 nm is 0.00055 mm when interpreting the displayed equations. The number called camera depth is the hole-to-image-plane distance; it is not the distance from the camera to a person. Confusing those two distances changes both the intended construction and the finite-distance blur interpretation.
Seven checks before a camera build
1. Establish the language, mode and baseline
Open the tool, choose your language and use Precision when you need all inputs visible. Enter the baseline values above or write down your own. Select the resolution chart to make repeated edge comparisons easier. Read the derived f-number and horizontal field of view before saving a reference; this catches a misplaced decimal or an unintended camera depth early.
2. Change one physical dimension
At 100 mm depth, change diameter from 0.45 to 0.90 mm while leaving manual time at 12 seconds. In our test, f/222 became f/111, relative illuminance became 4.00× and the meter fell from 12.1 to 3.0 seconds. Field of view stayed at 20.4°. A larger hole admitted more modelled light without widening the framing.
Then use Undo to return to the baseline. We confirmed that Undo restored the previous diameter. It is useful for a quick reversal, but an explicitly saved experiment is clearer when you need a named reference several changes later. Do not assume an Undo history is a portable project archive.
3. Fix A before judging B
Use the comparison reference controls, then move the A/B divider to reveal each side. We exercised the slider and compared the original 0.45 mm setup with a 0.36 mm setup. Confirm identical orientation and zoom first. A reference viewed at one magnification and a current image inspected at 2× can look different for reasons unrelated to optical blur.
For an aperture-only comparison, keep depth, scene, image width, subject distance and wavelength fixed. Decide whether exposure is also fixed: keeping 12 seconds answers a different question from matching each setup to its meter. State that choice in the saved note so a later viewer can interpret the brightness difference.
4. Read the two aperture recommendations
At 100 mm depth and 550 nm, Try the proxy minimum selected 0.36 mm. The separate Rayleigh starting point remained 0.45 mm. We then used Match metered exposure and obtained 18.8 seconds, f/278 and 0.64× relative illuminance. Treat these as starting configurations for a test, rather than competing promises of a uniquely best pinhole.
5. Check manual time against the meter
After every geometry, EV or ISO change, read both the calculated exposure and the manual-time field. The latter stayed at its previous value during our aperture and depth changes. Match metered exposure is convenient within range, but the manual control accepts only 0.1–120 seconds. Our EV 5 boundary test demonstrated that a longer computed reading can be capped when copied into that control.
The time theatre is helpful for thinking about motion. We changed its manual duration to 60 seconds and observed a 60.0-second display, then restored 18.8 with Undo. The source explains that the walking figure has normalized brightness. Do not use that figure as an independent test of actual photographic exposure or motion rendering.
6. Save, restore and share deliberately
Save an experiment after the settings are coherent. We saved 0.90 mm / 100 mm / 12 seconds and 0.36 mm / 100 mm / 18.8 seconds, then restored the latter. Both entries appeared on the Korean page in the same browser. That page initially showed default live controls; pressing Restore applied the saved values. Archive availability and automatic resumption of unsaved controls are different behaviours.
Share setup copied a URL with numeric parameters, scene, print style and orientation. Opening it in a new tab reproduced our 0.36 mm / 100 mm / 18.8-second configuration and resolution chart. Use that for a reproducible teaching setup. Keep a separate record of comparison intent and physical build notes; the link is not evidence that photos, the whole archive or reference A travel with it.
7. Review the plan before cutting material
Read the internal box dimensions and film dimensions in the blueprint section. Activate the A4 booklet control if you need the print path, and inspect the generated file yourself before fabrication. The tool reported an HTML print booklet in our session. Measure the specified 50 mm calibration bar on your own print at 100% scale before trusting the panel dimensions.
Actual browser test results
The following results came from live controls, not a physical optical bench. Unless a row says otherwise, image width was 36 mm, subject distance 2,000 mm, wavelength 550 nm, EV 12 and ISO 100. Manual time was not automatically changed by the calculator.
| Configuration | Derived output | What it demonstrates |
|---|---|---|
| Ø0.45 mm; depth 100 mm; manual 12 s | f/222; HFOV 20.4°; 1.00×; meter 12.1 s | Baseline |
| Ø0.90 mm; depth 100 mm; manual 12 s | f/111; HFOV 20.4°; 4.00×; meter 3.0 s | More light; same horizontal framing |
| Ø0.36 mm; depth 100 mm; matched 18.8 s | f/278; HFOV 20.4°; 0.64×; meter 18.8 s | Proxy-minimum setup |
| Ø0.36 mm; depth 50 mm; manual 18.8 s | f/139; HFOV 39.6°; 2.56×; meter 4.7 s | A shallower camera widens framing |
| Previous 50 mm setup; width 72 mm | f/139; HFOV 71.5°; meter 4.7 s | Wider image area changes framing, not f-number |
| Ø0.36 mm; depth 100 mm; EV 5 | Meter 2.4e+3 s; Match sets manual 120 s | Preview-time limit does not cover the whole meter range |
The aperture result is a useful sanity check: doubling diameter quadruples aperture area. In this model, the shorter matched time follows the added illumination. It does not imply that a real 0.90 mm handmade opening has the same shape, edge quality or off-axis behaviour as the idealized input. Those properties still need inspection at the bench.
How to interpret the sharpness graph
At 0.36 mm and 100 mm depth, the graph displayed 0.378 mm geometric blur and 0.373 mm Airy first-zero diameter. Their similar size explains the position of this model’s proxy minimum. The graph combines terms into a root-sum-square proxy; its vertical scale is not a measured modulation transfer function, and the scene is not a full Fresnel diffraction calculation.

Why can “optimal diameter” vary? Kjell Carlsson’s KTH paper explains that an optimum depends on the criterion used, including resolution and contrast transfer. That supports reading the two recommendations as different starting rules, rather than treating a single diameter as universally correct. See The pinhole camera: Science and Fun for the experimental context.
For a classroom demonstration, ask students to predict the direction of each change before moving a control. A smaller aperture reduces the geometric term but raises the diffraction term at fixed depth and wavelength. Afterwards, ask which inputs were held constant. This tests understanding more reliably than choosing whichever preview seems prettiest.
From screen dimensions to a physical camera
With a 36 × 22.5 mm image area and 100 mm depth, the onscreen plan showed an internal box of 76.0 × 62.5 × 100 mm. When we used 72 mm image width and 50 mm depth, it showed 112.0 × 85.0 × 50 mm and a 72 × 45.0 mm film area. Read these as internal planning dimensions; a thick board, joint overlap or separate film carrier can require adjustments.

The six panels are front, back, top, bottom and two sides. The source recommends opaque black card, light-tight taped seams, a foil window, a simple shutter and separate darkroom loading and development. Its printed pinhole dot is not a drill gauge. Make and measure the actual foil opening, and inspect for burrs rather than trusting the drawing’s dot size.
Do not tick the physical-readiness boxes just because the model looks plausible. Print scale, real aperture quality, closed shutter and light-tight seams each need their own check. The page also warns against looking at the Sun through a hole and notes sharp foil and cutting tools. We left the build checkboxes unchecked because no construction was performed.
Practical workflows and alternatives
A first paper-camera workshop
Start with one planned depth and an aperture you can actually measure. Save a baseline, compare a shallower box, then select a construction candidate. Keep the tool’s predicted exposure beside a blank column for the eventual test exposure and processing result. That separation makes it easy to learn from a failed sheet without rewriting the model output as if it were a real measurement.
An optics lesson without construction
Use the resolution chart, fixed EV and a constant manual time to discuss light and sharpness separately. Change image width next while keeping depth fixed, then explain why field of view changes even though the f-number does not. The editable setup URL helps a teacher reproduce the exercise on another tab; students should still save their own observations.
A photographic workflow after the model
For film-specific long exposures, continue with LATENTIME’s film exposure and reciprocity checks. Check its evidence for the selected film and avoid applying aperture or other factors twice to an exposure that already includes them. OBSCURAFORGE’s EV/ISO meter alone does not establish a manufacturer-specific reciprocity correction.
Once a negative exists, PRINTSCORE’s dodging and burning planner addresses a later darkroom printing task. After development and scanning, NEGAPROOF’s film proof workflow can organize positive scan images and selection notes. These are separate tools; we verified no automatic project transfer between them.
A spreadsheet is a reasonable alternative if you only need f/d and field-of-view calculations with your own notes. A real test camera is the next step when material response, vignetting, light leaks and construction tolerances are the questions. The simulator earns its place between those options by making geometric changes visible and tying them to a preliminary plan.
Limitations, exports and privacy
Model limits: thick or irregular holes, broadband illumination, film grain, chemistry, close objects and wide-angle edge behaviour are not fully captured by this educational preview. It cannot certify a final exposure, measured sharpness or a build’s light-tightness. The displayed subject distance and wavelength are modelling choices, not properties inferred from an uploaded photograph.
Output verification: A4 download produced an onscreen message that an HTML booklet had been generated and should be printed at actual size. We also activated Save image PNG and JSON export, but did not inspect completed files. We did not test JSON import, photo attachment, printed scale or assembly. The interface advertises an eight-experiment archive and a 5 MB photo limit; we tested two entries, not those capacity boundaries.
Reasoning exercises: Optical Detective presents controlled examples. Choosing two pinholes and then covering one produced a demonstration in which one copy disappears. That is a teaching response to a selected scenario, not an automated diagnosis of our photograph. Camera movement or reflection can need different investigation.
Privacy: the publisher says uploaded photos and experiments stay in the browser until deleted or site data is cleared. Our cross-language archive observation is consistent with local continuity in this browser; it is not an independent network or security audit. The same privacy panel identifies Blogger/Google hosting, Google Fonts and AdSense cookies or identifiers. “Local experiments” therefore does not mean the entire page is offline or free of third-party services.
No sign-in or payment was needed for the tested controls. Ads were visible. We did not test offline use or every browser. On a shared device, consider who can access saved photographs and browser data. Before clearing site storage or switching devices, keep any settings and notes you need somewhere you control; a setup URL alone is not a photo archive.
Frequently asked questions
Does a smaller hole always make the image sharper?
No. In this model it reduces geometric blur while increasing the diffraction estimate at fixed depth. The 0.36 mm proxy minimum and 0.45 mm Rayleigh starting point illustrate how the preferred value also depends on the criterion. Verify the real hole and photographic result separately.
Why did the preview time stay at 12 seconds?
The manual field and calculated meter are separate. We saw the meter fall to 3.0 seconds after doubling diameter while manual time remained 12. Match metered exposure updates the manual value within its 120-second maximum; it cannot represent every longer computed exposure.
Does A4 download mean a ready-made PDF?
The tool reported an HTML print booklet in our test. We did not inspect a downloaded file or print it. Do not promise PDF output or a calibrated physical template on that evidence. Open your own generated booklet and check the 50 mm reference bar at actual size.
Can I resume on the Korean page?
Two saved experiments appeared there in the same browser. The live controls first showed their defaults, and Restore applied our saved configuration. We did not verify archive transfer to another device or an import/export round trip. Share setup reproduced parameters in another tab, which is a narrower capability.
Is it usable on a phone?
At 390 px we restored a saved experiment, opened the photo-result view, changed depth to 50 mm and used Undo. The values matched the desktop calculation. Dense diagrams still need careful reading on a small screen; use the numeric readouts for a comparison rather than relying only on the image.
Start with one controlled comparison
Open a pinhole camera baseline, save A, then change only diameter. Write down f-number, field of view, meter and manual time before deciding which setup deserves a physical test. That small record turns an attractive optics demonstration into a useful build decision.